ДСТУ EN 60534-2-3:2022 Регулювальні клапани для промислових процесів. Частина 2-3. Пропускна здатність. Процедури випробувань (EN 60534-2-3:2016, IDT; IEC 60534-2-3:2015, IDT)
ДСТУ EN 60534-2-3:2022
(EN 60534-2-3:2016, IDT; IEC 60534-2-3:2015, IDT)
Регулювальні клапани для промислових процесів.
Частина 2-3. Пропускна здатність. Процедури
випробувань
Не є офіційним виданням.
Офіційне видання розповсюджує національний орган стандартизації
(ДП «УкрНДНЦ» http://uas.gov.ua)
CONTENTS
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 Test system
5.1 Test specimen
5.2 Test section
5.3 Throttling valves
5.4 Flow measurement
5.5 Pressure taps
5.6 Pressure measurement
5.7 Temperature measurement
5.8 Valve travel
5.9 Installation of test specimen
6 Accuracy of tests
7 Test fluids
7.1 Incompressible fluids
7.2 Compressible fluids
8 Test procedure for incompressible fluids
8.1 Test procedure for flow coefficient C
8.2 Test procedure for liquid pressure recovery factor FL and combined liquid pressure recovery factor and piping geometry factor FLP
8.3 Test procedure for piping geometry factor FP
8.4 Test procedure for liquid critical pressure ratio factor FF
8.5 Test procedure for Reynolds number factor FR for incompressible flow
8.6 Test procedure for valve style modifier FD
9 Data evaluation procedure for incompressible fluids
9.1 Non-choked flow
9.2 Choked flow
9.3 Calculation of flow coefficient C
9.4 Calculation of liquid pressure recovery factor FL and the combined liquid pressure recovery factor and piping geometry factor FLP
9.5 Calculation of piping geometry factor FP
9.6 Calculation of liquid critical pressure ratio factor FF
9.7 Calculation of Reynolds number factor FR
9.8 Calculation of valve style modifier Fd
10 Test procedure for compressible fluids
10.1 Test procedure for flow coefficient C
10.2 Test procedure for pressure differential ratio factors xT and xTP
10.3 Test procedure for piping geometry factor Fp
10.4 Test procedure for Reynolds number factor FR
10.5 Test procedure for valve style modifier Fd
10.6 Test procedure for small flow trim
11 Data evaluation procedure for compressible fluids
11.1 Flow equation
11.2 Calculation of flow coefficient C
11.3 Calculation of pressure differential ratio factor xT
11.4 Calculation of pressure differential ratio factor xTP
11.5 Calculation of piping geometry factor Fp
11.6 Calculation of Reynolds number factor FR for compressible fluids
11.7 Calculation of valve style modifier Fd
11.8 Calculation of flow coefficient C for small flow trim
Annex A (normative) Typical examples of test specimens showing appropriate pressure tap locations
Annex B (informative) Engineering data
Annex C (informative) Derivation of the valve style modifier, Fd
Annex D (informative) Laminar flow test discussion
Annex E (informative) Long form FL test procedure
Annex F (informative) Calculation of FP to help determine if pipe/valve port diameters are adequately matched
Bibliography