Contents
Foreword
1 Scope
2 Normative references
3 Terms, definitions, abbreviated terms and symbols
3.1 Terms and definitions
3.2 Abbreviated terms
3.3 Symbols
4 Representative voltage stresses in service
4.1 Origin and classification of voltage stresses
4.2 Characteristics of overvoltage protection devices
4.3 Representative voltages and overvoltages
5 Co-ordination withstand voltage
5.1 Insulation strength characteristics
5.2 Performance criterion
5.3 Insulation co-ordination procedures
6 Required withstand voltage
6.1 General remarks
6.2 Atmospheric correction
6.3 Safety factors
7 Standard withstand voltage and testing procedures
7.1 General remarks
7.2 Test conversion factors
7.3 Determination of insulation withstand by type tests
8 Special considerations for overhead lines
8.1 General remarks
8.2 Insulation co-ordination for operating voltages and temporary overvoltages
8.3 Insulation co-ordination for slow-front overvoltages
8.4 Insulation co-ordination for lightning overvoltages
9 Special considerations for substations
9.1 General remarks
9.2 Insulation co-ordination for overvoltages
Annex A (informative) Determination of temporary overvoltages due to earth faults
Annex B (informative) Weibull probability distributions
Annex C (informative) Determination of the representative slow-front overvoltage due to line energization and re-energization
Annex D (informative) Transferred overvoltages in transformers
Annex E (informative) Lightning overvoltages
Annex F (informative) Calculation of air gap breakdown strength from experimental data
Annex G (informative) Examples of insulation co-ordination procedure
Annex H (informative) Atmospheric correction - Altitude correction
Annex I (informative) Evaluation method of non-standard lightning overvoltage shape for representative voltages and overvoltages
Annex J (informative) Insulation co-ordination for very-fast-front overvoltages in UHV substations
Bibliography
Annex ZA (normative) Normative references to international publications with their corresponding European publications