ДСТУ EN IEC 61400-12-3:2025 Системи вітроенергетичні. Частина 12-3. Вимірювання потужності. Калібрування на основі вимірювань (EN IEC 61400-12-3:2022, IDT; IEC 61400-12-3:2022, IDT)
ДСТУ EN IEC 61400-12-3:2025
(EN IEC 61400-12-3:2022, IDT; IEC 61400-12-3:2022, IDT)
Системи вітроенергетичні. Частина 12-3. Вимірювання потужності. Калібрування на основі вимірювань
Не є офіційним виданням.
Офіційне видання розповсюджує національний орган стандартизації
(ДП «УкрНДНЦ» http://uas.gov.ua)
Contents
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols, units and abbreviated terms
5 General
6 Overview of the procedure
7 Test set-up
7.1 Considerations for selection of the test wind turbine and location of the meteorological mast
7.1.1 General
7.1.2 Type A:
7.1.3 Type B:
7.1.4 Type C:
7.2 Instrumentation
8 Data acquisition and rejection criteria
9 Analysis
9.1 General
9.2 Assessment of site shear conditions
9.2.1 Shear calculations and characterisation plots
9.2.2 Assess significance of shear
9.2.3 Establish correlation of shear between locations
9.3 Method 1: Bins of wind direction and wind shear
9.4 Method 2: Linear regression method where wind shear is not a significant influence
9.5 Additional calculations
10 Site calibration uncertainty
10.1 Site calibration category A uncertainty
10.1.1 Site calibration k-fold analysis
10.1.2 Site calibration statistical uncertainty for each fold
10.2 Site calibration category B uncertainty
10.2.1 General
10.2.2 Anemometer - Pre-calibration
10.2.3 Anemometer - Post-calibration
10.2.4 Anemometer - Classification
10.2.5 Anemometer - Mounting
10.2.6 Anemometer - Data acquisition
10.2.7 Anemometer - Lightning finial
10.3 Combining uncertainties in the wind speed measurement from flow distortion due to site calibration uVT,i
10.4 Combined uncertainty
11 Quality checks and additional uncertainties
11.1 Convergence check
11.2 Correlation check for linear regression (see 9.4)
11.3 Change in correction between adjacent wind direction bins
11.3.1 General
11.3.2 Removal of the wind direction sensor between site calibration and power performance test
11.4 Site calibration and power performance measurements in different seasons
Annex A (informative) Verification of results
Annex B (informative) Site calibration examples
B.1 Example A
B.1.1 Site description:
B.1.2 Site calibration setup:
B.1.3 Site calibration evaluation:
B.1.4 Step 1: Check the significance of wind shear at the site according to 9.2.2:
B.1.5 Step 2: Verify correlation of wind shear at wind turbine and reference meteorological mast locations - Example A
B.1.6 Step 3: Calculate results according to 9.2.3
B.1.7 Step 4: Quality checks and additional uncertainties
B.2 Example B
B.2.1 Site description:
B.2.2 Site calibration setup:
B.2.3 Step 1: Check the significance of wind shear at the site:
B.2.4 Step 2A: Verify correlation of wind shear at wind turbine and reference meteorological mast locations, example B
B.2.5 Step 2B: Attempt to remove non-correlating wind shear data
B.2.6 Step 3: Calculate results
B.2.7 Step 4: Additional uncertainties:
B.3 Example C
B.3.1 Site description:
B.3.2 Site calibration setup:
B.3.3 Step 1: Check the significance of wind shear at the site:
B.3.4 Step 2: Verify correlation of wind shear at wind turbine and reference meteorological mast locations, example C
B.3.5 Step 3: Calculate results
B.3.6 Step 4: Quality checks and uncertainty
B.3.7 Anemometer operational uncertainty:
B.3.8 Convergence check:
B.3.9 Change in magnitude of correction between bins:
B.3.10 Wind vane adjustment:
B.3.11 Seasonal uncertainty adjustment:
Bibliography
Повна версія документа доступна в тарифі «ВСЕ ВРАХОВАНО».



